New user? / Forgot your password?
0 Item | 0,00 €
Item number | 674646 |
CAS | 108-78-1 |
Formula | C3H6N6 |
Molecular weight | 126,12 g/mol |
Quantity | 1X250MG |
storage conditions | 20 °C |
CoA / MSDS | Retrieve CoA Retrieve MSDS |
Product | Catalog No./ CAS No. | Quantity | Price | |
---|---|---|---|---|
679703 | 1X10MG | Please log in. | ||
13C3-Melamine solution | 690782 | 1X1ML | Please log in. | |
673055 | 1X10MG | Please log in. | ||
674646 | 1X250MG | Please log in. |
Safety Data Sheet | according to Regulation (EC) No 1907/2006 (REACH) Classifications according to Regulation (EC) No 1272/2008. Printdate 06.10.2024 |
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING | |
Product name: | Melamine |
Catalog No.: | 674646 |
Relevant identified uses of the substance or mixture | Identified: Laboratory chemical uses: R&D |
Uses advised against: | HPC Standards GmbH Am Wieseneck 7 04451 Cunnersdorf Deutschland Tel. +49 34291 3372-36 Fax. +49 34291 3372-39 contact@hpc-standards.com |
Emergency telephone number | HPC Standards Tel. +49 34291 3372-36 This number is only available during office hours. |
HAZARDS IDENTIFICATION | 2.1 Classification of the substance or mixture Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008. This substance is not classified as dangerous according to Directive 67/548/EEC |
Label elements | |
Pictogram | |
2.2 Label elements The product does not need to be labelled in accordance with EC directives or respective national laws. 2.3 Other hazards This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher | |
COMPOSITION/INFORMATION ON INGREDIENTS | 3.1 Substances Synonyms : 2,4,6-Triamino-1,3,5-triazine sym-Triaminotriazine Formula : C3H6N6 Molecular weight : 126,12 g/mol CAS-No. : 108-78-1 EC-No. : 203-615-4 No components need to be disclosed according to the applicable regulations |
Formula | C3H6N6 |
Molecular Weight (g/mol) | 126.12 |
CAS-No. | 108-78-1 |
FIRST AID MEASURES | 4.1 Description of first aid measures If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. In case of skin contact Wash off with soap and plenty of water. In case of eye contact Flush eyes with water as a precaution. If swallowed Never give anything by mouth to an unconscious person. Rinse mouth with water. 4.2 Most important symptoms and effects, both acute and delayed The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 4.3 Indication of any immediate medical attention and special treatment needed No data available |
FIRE-FIGHTING MEASURES | 5.1 Extinguishing media Suitable extinguishing media Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. 5.2 Special hazards arising from the substance or mixture Carbon oxides, nitrogen oxides (NOx) 5.3 Advice for firefighters Wear self contained breathing apparatus for fire fighting if necessary. 5.4 Further information no data available |
ACCIDENTAL RELEASE MEASURES | 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Avoid breathing dust. 6.2 Environmental precautions Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal. 6.4 Reference to other sections For disposal see section 13. |
HANDLING AND STORAGE | 7.1 Precautions for safe handling Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. 7.2 Conditions for safe storage, including any incompatibilities Store in cool place. Keep container tightly closed in a dry and well-ventilated place. 7.3 Specific end uses no data available |
EXPOSURE CONTROLS/PERSONAL PROTECTION | 8.1 Control parameters Components with workplace control parameters 8.2 Exposure controls Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. Personal protective equipment Eye/face protection Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Body Protection Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Respiratory protection Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). |
PHYSICAL AND CHEMICAL PROPERTIES | 9.1 Information on basic physical and chemical properties a) Appearance Form: solid b) Odour No data available c) Odour Threshold No data available d) pH No data available e) Melting point/freezing point Melting point/range: > 300 °C - lit. f) Initial boiling point and boiling range No data available g) Flash point 300 °C - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) May form combustible dust concentrations in air j) Upper/lower flammability or explosive limits No data available k) Vapour pressure No data available l) Vapour density No data available m) Relative density No data available n) Water solubility 3,48 g/l at 20 °C o) Partition coefficient: noctanol/ water log Pow: -1,219 at 22 °C p) Auto-ignition temperature > 400 °C at 1.013 hPa q) Decomposition temperature No data available r) Viscosity No data available s) Explosive properties No data available t) Oxidizing properties No data available 9.2 Other safety information No data available |
STABILITY AND REACTIVITY | 10.1 Reactivity no data available 10.2 Chemical stability no data available 10.3 Possibility of hazardous reactions no data available 10.4 Conditions to avoid no data available 10.5 Incompatible materials Strong oxidizing agents, Strong acids 10.6 Hazardous decomposition products Other decomposition products - no data available |
TOXICOLOGICAL INFORMATION | 11.1 Information on toxicological effects Acute toxicity LD50 Oral - Rat - male - 3.161 mg/kg LC50 Inhalation - Rat - male and female - 4 h - > 5.190 mg/m3 LD50 Dermal - Rabbit - > 1.000 mg/kg Skin corrosion/irritation Skin - Rabbit Result: No skin irritation Serious eye damage/eye irritation Eyes - Rabbit Result: Mild eye irritation - 24 h Respiratory or skin sensitisation Maximisation Test (GPMT) - Guinea pig Did not cause sensitisation on laboratory animals. (OECD Test Guideline 406) Germ cell mutagenicity Laboratory experiments have shown mutagenic effects. in vitro assay S. typhimurium Result: negative Mouse - male Result: negative Carcinogenicity Carcinogenicity - Rat - Oral Tumorigenic:Carcinogenic by RTECS criteria. Kidney, Ureter, Bladder:Tumors. This product is or contains a component that is not classifiable as to its carcinogenicity based on its IARC, ACGIH, NTP, or EPA classification. IARC: 3 - Group 3: Not classifiable as to its carcinogenicity to humans (Melamine) Reproductive toxicity Reproductive toxicity - Rat - Inhalation Paternal Effects: Spermatogenesis (including genetic material, sperm morphology,motility, and count). Effects on Fertility: Pre-implantation mortality (e.g., reduction in number of implants per female; total number of implants per corpora lutea). Effects on Embryo or Fetus: Fetal death. Specific target organ toxicity - single exposure No data available Specific target organ toxicity - repeated exposure No data available Aspiration hazard No data available Additional Information Repeated dose toxicity - Rat - male - Oral - Lowest observed adverse effect level - 72 mg/kg RTECS: OS0700000 To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated |
ECOLOGICAL INFORMATION | 12.1 Toxicity no data available 12.2 Persistence and degradability no data available 12.3 Bioaccumulative potential no data available 12.4 Mobility in soil no data available 12.5 Results of PBT and vPvB assessment no data available 12.6 Other adverse effects no data available |
DISPOSAL CONSIDERATIONS | 13.1 Waste treatment methods Product Offer surplus and non-recyclable solutions to a licensed disposal company. Contaminated packaging Dispose of as unused product. |
TRANSPORT INFORMATION | 14.1 UN number ADR/RID: - IMDG: - IATA: - 14.2 UN proper shipping name ADR/RID: Not dangerous goods IMDG: Not dangerous goods IATA: Not dangerous goods 14.3 Transport hazard class(es) ADR/RID: - IMDG: - IATA: - 14.4 Packaging group ADR/RID: - IMDG: - IATA: - 14.5 Environmental hazards ADR/RID: no IMDG Marine pollutant: no IATA: no 14.6 Special precautions for user no data available |
REGULATORY INFORMATION | This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006. 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture no data available 15.2 Chemical Safety Assessment no data available |
OTHER INFORMATION | The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. For lab use only! |